Indukta

» three phase induction explosion-proof increased safety motors


» II 2G Ex e II T3 Sg 100L-2
» II 2G Ex e II T3 Sg 100L-4A
» II 2G Ex e II T3 Sg 100L-4B
» II 2G Ex e II T3 Sg 100L-6
» II 2G Ex e II T3 Sg 112M-2
» II 2G Ex e II T3 Sg 112M-4
» II 2G Ex e II T3 Sg 112M-6
» II 2G Ex e II T3 Sg 132M-4
» II 2G Ex e II T3 Sg 132M-6A
» II 2G Ex e II T3 Sg 132M-6B
» II 2G Ex e II T3 Sg 132S-2A
» II 2G Ex e II T3 Sg 132S-2B
» II 2G Ex e II T3 Sg 132S-4
» II 2G Ex e II T3 Sg 132S-6
» II 2G Ex e II T3 Sg 160L-2
» II 2G Ex e II T3 Sg 160L-4
» II 2G Ex e II T3 Sg 160L-6
» II 2G Ex e II T3 Sg 160M-2A
» II 2G Ex e II T3 Sg 160M-4
» II 2G Ex e II T3 Sg 160M-6
» II 2G Ex e II T3 Sg 180L-4
» II 2G Ex e II T3 Sg 180L-6
» II 2G Ex e II T3 Sg 180M-2
» II 2G Ex e II T3 Sg 180M-4
» II 2G Ex e II T3 Sh 90L-2
» II 2G Ex e II T3 Sh 90L-4
» II 2G Ex e II T3 Sh 90L-6
» II 2G Ex e II T3 Sh 90S-2
» II 2G Ex e II T3 Sh 90S-4
» II 2G Ex e II T3 Sh 90S-6
» II 2G Ex e II T4 Sg 100L-2
» II 2G Ex e II T4 Sg 100L-4A
» II 2G Ex e II T4 Sg 100L-4B
» II 2G Ex e II T4 Sg 100L-6
» II 2G Ex e II T4 Sg 112M-2
» II 2G Ex e II T4 Sg 112M-4
» II 2G Ex e II T4 Sg 112M-6
» II 2G Ex e II T4 Sg 132M-4
» II 2G Ex e II T4 Sg 132M-6A
» II 2G Ex e II T4 Sg 132M-6B
» II 2G Ex e II T4 Sg 132S-2A
» II 2G Ex e II T4 Sg 132S-2B
» II 2G Ex e II T4 Sg 132S-4
» II 2G Ex e II T4 Sg 132S-6
» II 2G Ex e II T4 Sg 160L-2
» II 2G Ex e II T4 Sg 160L-4
» II 2G Ex e II T4 Sg 160L-6
» II 2G Ex e II T4 Sg 160M-2A
» II 2G Ex e II T4 Sg 160M-2B
» II 2G Ex e II T4 Sg 160M-4
» II 2G Ex e II T4 Sg 160M-6
» II 2G Ex e II T4 Sg 180L-4
» II 2G Ex e II T4 Sg 180M-2
» II 2G Ex e II T4 Sh 90L-2
» II 2G Ex e II T4 Sh 90L-4
» II 2G Ex e II T4 Sh 90L-6
» II 2G Ex e II T4 Sh 90S-2
» II 2G Ex e II T4 Sh 90S-4
» II 2G Ex e II T4 Sh 90S-6

II 2G Ex e II T4 Sh 90L-6

add to notebook



basic information

frame size 90
EN 60034-1. EN 50019
type of duty S1
explosionproof II 2G EEx e II T4
cooling system IC 411
insulation class F

exploitation parameters

rated output [kW] 0.80
synchronous speed [rpm] 1000
rated voltage 1 [V] 400
frequency [Hz] 50
current at rated voltage 1 [A] 2.6
rated output [HP] 1.07
rated torque [Nm] 8.04
number of poles 6
efficiency (1/4 load) [%] 51.2
efficiency (1/2 load) [%] 66.0
efficiency (3/4 load) [%] 71.7
efficiency (full load) [%] 73.9
efficiency (5/4 load) [%] 73.8
power factor (1/4 load) 0.27
power factor (1/2 load) 0.40
power factor (3/4 load) 0.52
power factor (full load) 0.61
power factor (5/4 load) 0.68
rated voltage 2 [V] 230
rated voltage 3 [V] 500
rated voltage 4 [V] -
current at rated voltage 2 [A] 4.5
current at rated voltage 3 [A] 2.1
current at rated voltage 4 [A] -
winding connection Y
star/delta start No
locked rotor torque/rated troque 3.1
locked rotor current/rated current 4.75
breakdown torque/rated torque 3.3
minimal torque/rated torque 3.0
locked rotor torque [Nm] 24.9
locked rotor current at rated voltage 1 [A] 12.1
breakdown torque [Nm] 26.8
minimal torque [Nm] 23.9
sound power level [dB] -
sound pressure level [dB] -

technical data

weight (IMB3) [kg] 15.5
supplying with frequency inverter No
rotor inertia [kgm2] 0.0028
relative humidity [%] 95
DE bearing 6205 2Z
NDE bearing 6205 2Z
position of terminal box Top
terminal box rotation Yes
number of terminals 6
number of cable outlets 2
gland M20 x 1.5
thermal protection of windings On request
grease fittings No
anticondensation heaters No
frame Aluminium
end shields Aluminium
foot Aluminium

Cantoni MotorBeselInduktaCelmaEmitEma-ElfaFanaFormitNarmodFenes