Indukta

Sg 132S-6/4

add to notebook



basic information

IEC 60034-1;PN-EN 60034-
insulation class F
type of duty S1
cooling system IC 411
degree of protection IP 55
frame size 132

exploitation parameters

rated output [kW] 2.5/3.5
synchronous speed [rpm] 1000/1500
frequency [Hz] 50
rated voltage 1 [V] 400
current at rated voltage 1 [A] 6.4
breakdown torque [Nm] 64
locked rotor torque [Nm] 44.3
winding connection Y
minimal torque [Nm] 42
locked rotor current at rated voltage 1 [A] 33.9
minimal torque/rated torque 1.7
breakdown torque/rated torque 2.6
locked rotor current/rated current 5.3
locked rotor torque/rated troque 1.8
star/delta start nie/no
efficiency (3/4 load) [%] 75.4
efficiency (1/2 load) [%] 70.4
efficiency (1/4 load) [%] 57.3
number of poles 6/4
rated torque [Nm] 24.61
rated output [HP] 3.40/4.8
efficiency (full load) [%] 77
efficiency (5/4 load) [%] 76.6
power factor (1/4 load) 0.32
current at rated voltage 3 [A] 5.1
current at rated voltage 2 [A] 6.7
rated voltage 3 [V] 500
rated voltage 2 [V] 380
power factor (5/4 load) 0.8
power factor (full load) 0.74
power factor (3/4 load) 0.63
power factor (1/2 load) 0.50

technical data

weight (IMB3) [kg] 60
rotor inertia [kgm2] 0.032
climate on request
relative humidity [%] 95
foot cast iron
end shields cast iron
frame cast iron
anticondensation heaters on request
grease fittings on request
thermal protection of windings on request
gland M 25 x 1.5
number of cable outlets 2
number of terminals 6
terminal box rotation yes
position of terminal box top
NDE bearing 6308 2Z
DE bearing 6308 2Z

mounting arrangements

IM 1001 / IM B3 Sg_132S.pdf
IM 1051 / IM B6 Sg_132S.pdf
IM 1061 / IM B7 Sg_132S.pdf
IM 1071 / IM B8 Sg_132S.pdf
IM 2001 / IM B35 SLg_132S.pdf
IM 3001 / IM B5 SKg_132S.pdf
IM 1011 / IM V5 Sg_132S.pdf
IM 1031 / IM V6 Sg_132S.pdf
IM 2011 / IM V15 SLg_132S.pdf
IM 2031 / IM V36 available
IM 3011 / IM V1 SKg_132S.pdf
IM 3031 / IM V3 SKg_132S.pdf

Cantoni MotorBeselInduktaCelmaEmitEma-ElfaFanaFormitNarmodFenes