Indukta

Sg 112M-6/4W

add to notebook



basic information

insulation class F
IEC 60034-1;PN-EN 60034-
degree of protection IP 55
type of duty S1
cooling system IC 411
frame size 112

exploitation parameters

rated output [kW] 0.9/3
synchronous speed [rpm] 1000/1500
frequency [Hz] 50
rated voltage 1 [V] 400
current at rated voltage 1 [A] 2.6
power factor (1/2 load) 0.47
power factor (3/4 load) 0.6
power factor (full load) 0.69
power factor (5/4 load) 0.76
rated voltage 2 [V] 380
rated voltage 3 [V] 500
current at rated voltage 2 [A] 2.7
current at rated voltage 3 [A] 2.1
power factor (1/4 load) 0.32
efficiency (5/4 load) [%] 73.1
efficiency (full load) [%] 73
rated output [HP] 1.21/4
rated torque [Nm] 8.82
number of poles 6/4
efficiency (1/4 load) [%] 50.1
efficiency (1/2 load) [%] 64.9
efficiency (3/4 load) [%] 70.8
star/delta start nie/no
locked rotor torque/rated troque 2.1
locked rotor current/rated current 5.5
breakdown torque/rated torque 3
minimal torque/rated torque 1.8
locked rotor torque [Nm] 18.52
locked rotor current at rated voltage 1 [A] 14.3
breakdown torque [Nm] 26
minimal torque [Nm] 15.9
winding connection Y

technical data

weight (IMB3) [kg] 33.3
DE bearing 6306 2Z
NDE bearing 6306 2Z
position of terminal box top
terminal box rotation yes
number of terminals 6
number of cable outlets 2
gland M 25 x 1.5
thermal protection of windings on request
grease fittings on request
anticondensation heaters on request
frame aluminium
end shields cast iron
foot aluminium
relative humidity [%] 95
climate on request
rotor inertia [kgm2] 0.0178

mounting arrangements

IM 1001 / IM B3 Sg_112.pdf
IM 1051 / IM B6 Sg_112.pdf
IM 1061 / IM B7 Sg_112.pdf
IM 1071 / IM B8 Sg_112.pdf
IM 2001 / IM B35 SLg_112.pdf
IM 3001 / IM B5 SKg_112.pdf
IM 1011 / IM V5 Sg_112.pdf
IM 1031 / IM V6 Sg_112.pdf
IM 2011 / IM V15 SLg_112.pdf
IM 2031 / IM V36 available
IM 3011 / IM V1 SKg_112.pdf
IM 3031 / IM V3 SKg_112.pdf