» ventilator motors
» Sg 100L-4/2AW
» Sg 100L-4/2BW
» Sg 100L-6/4AW
» Sg 100L-6/4BW
» Sg 100L-8/4AW
» Sg 100L-8/4BW
» Sg 100L-8/4W
» Sg 100L-8/6AW
» Sg 100L-8/6BW
» Sg 112M-12/6W
» Sg 112M-4/2W
» Sg 112M-6/4W
» Sg 112M-8/4W
» Sg 112M-8/4WB
» Sg 112M-8/6W
» Sg 132M-4/2W
» Sg 132M-4/2WB
» Sg 132M-6/4W
» Sg 132M-8/4W
» Sg 132M-8/4WB
» Sg 132S-4/2W
» Sg 132S-4/2WB
» Sg 132S-6/4W
» Sg 132S-8/4W
» Sg 132S-8/4WB
» Sg 132S-8/6W
» Sg 160L-4/2W
» Sg 160L-6/4W
» Sg 160L-8/4W
» Sg 160M-4/2W
» Sg 160M-6/4W
» Sg 160M-8/4W
» Sg 180L-4/2W
» Sg 180L-6/4W
» Sg 180L-8/4W
» Sg 180M-4/2W
» Sh 90L-4/2W
» Sh 90L-6/4W
» Sh 90L-8/4W
» Sh 90L-8/6W
» Sh 90S-4/2W
» Sh 90S-6/4W
» Sh 90S-8/4W
» Sh 90S-8/6W
» Three-phase multiple-speed motors for fans 'W' serie
» Three-phase multiple-speed motors for fans 'Q' serie
» Three-phase marine motors for axial-flow ventilators
» Three-phase multiple-speed motors for fans 'Q' serie
» Three-phase marine motors for axial-flow ventilators
» Sg 100L-4/2AW
» Sg 100L-4/2BW
» Sg 100L-6/4AW
» Sg 100L-6/4BW
» Sg 100L-8/4AW
» Sg 100L-8/4BW
» Sg 100L-8/4W
» Sg 100L-8/6AW
» Sg 100L-8/6BW
» Sg 112M-12/6W
» Sg 112M-4/2W
» Sg 112M-6/4W
» Sg 112M-8/4W
» Sg 112M-8/4WB
» Sg 112M-8/6W
» Sg 132M-4/2W
» Sg 132M-4/2WB
» Sg 132M-6/4W
» Sg 132M-8/4W
» Sg 132M-8/4WB
» Sg 132S-4/2W
» Sg 132S-4/2WB
» Sg 132S-6/4W
» Sg 132S-8/4W
» Sg 132S-8/4WB
» Sg 132S-8/6W
» Sg 160L-4/2W
» Sg 160L-6/4W
» Sg 160L-8/4W
» Sg 160M-4/2W
» Sg 160M-6/4W
» Sg 160M-8/4W
» Sg 180L-4/2W
» Sg 180L-6/4W
» Sg 180L-8/4W
» Sg 180M-4/2W
» Sh 90L-4/2W
» Sh 90L-6/4W
» Sh 90L-8/4W
» Sh 90L-8/6W
» Sh 90S-4/2W
» Sh 90S-6/4W
» Sh 90S-8/4W
» Sh 90S-8/6W
Sg 132M-8/4W
add to notebookbasic information |
|
|---|---|
| insulation class | F |
| IEC 60034-1;PN-EN 60034- | |
| degree of protection | IP 55 |
| type of duty | S1 |
| cooling system | IC 411 |
| frame size | 132 |
exploitation parameters |
|
|---|---|
| rated output [kW] | 1.4/5.3 |
| synchronous speed [rpm] | 750/1500 |
| frequency [Hz] | 50 |
| rated voltage 1 [V] | 400 |
| current at rated voltage 1 [A] | 3.6 |
| power factor (1/2 load) | 0.57 |
| power factor (3/4 load) | 0.69 |
| power factor (full load) | 0.75 |
| power factor (5/4 load) | 0.78 |
| rated voltage 2 [V] | 380 |
| rated voltage 3 [V] | 500 |
| current at rated voltage 2 [A] | 3.8 |
| current at rated voltage 3 [A] | 2.9 |
| power factor (1/4 load) | 0.38 |
| efficiency (5/4 load) [%] | 69.3 |
| efficiency (full load) [%] | 74.6 |
| rated output [HP] | 1.9/7.2 |
| rated torque [Nm] | 19.1 |
| number of poles | 8/4 |
| efficiency (1/4 load) [%] | 68 |
| efficiency (1/2 load) [%] | 76 |
| efficiency (3/4 load) [%] | 77.5 |
| star/delta start | nie/no |
| locked rotor torque/rated troque | 1.3 |
| locked rotor current/rated current | 3.6 |
| breakdown torque/rated torque | 1.9 |
| locked rotor torque [Nm] | 24.83 |
| locked rotor current at rated voltage 1 [A] | 13 |
| breakdown torque [Nm] | 36 |
| winding connection | Y |
technical data |
|
|---|---|
| weight (IMB3) [kg] | 66 |
| DE bearing | 6308 2Z |
| NDE bearing | 6308 2Z |
| position of terminal box | top |
| terminal box rotation | yes |
| number of terminals | 6 |
| number of cable outlets | 2 |
| gland | M 25 x 1.5 |
| thermal protection of windings | on request |
| grease fittings | on request |
| anticondensation heaters | on request |
| frame | cast iron |
| end shields | cast iron |
| foot | cast iron |
| relative humidity [%] | 95 |
| climate | on request |
| rotor inertia [kgm2] | 0.04 |
mounting arrangements |
|
|---|---|
| IM 1001 / IM B3 | Sg_132M.pdf |
| IM 1051 / IM B6 | Sg_132M.pdf |
| IM 1061 / IM B7 | Sg_132M.pdf |
| IM 1071 / IM B8 | Sg_132M.pdf |
| IM 2001 / IM B35 | SLg_132M.pdf |
| IM 3001 / IM B5 | SKg_132M.pdf |
| IM 1011 / IM V5 | Sg_132M.pdf |
| IM 1031 / IM V6 | Sg_132M.pdf |
| IM 2011 / IM V15 | SLg_132M.pdf |
| IM 2031 / IM V36 | available |
| IM 3011 / IM V1 | SKg_132M.pdf |
| IM 3031 / IM V3 | SKg_132M.pdf |