Indukta

Sg 100L-8/6BW

add to notebook



basic information

insulation class F
IEC 60034-1;PN-EN 60034-
degree of protection IP 55
type of duty S1
cooling system IC 411
frame size 100

exploitation parameters

rated output [kW] 0.6/1.25
synchronous speed [rpm] 750/1000
frequency [Hz] 50
rated voltage 1 [V] 400
current at rated voltage 1 [A] 2.4
power factor (1/2 load) 0.44
power factor (3/4 load) 0.54
power factor (full load) 0.63
power factor (5/4 load) 0.7
rated voltage 2 [V] 380
rated voltage 3 [V] 500
current at rated voltage 2 [A] 2.5
current at rated voltage 3 [A] 1.9
power factor (1/4 load) 0.34
efficiency (5/4 load) [%] 59.4
efficiency (full load) [%] 57.9
rated output [HP] 0.81/1.7
rated torque [Nm] 7.96
number of poles 8/6
efficiency (1/4 load) [%] 30.4
efficiency (1/2 load) [%] 45.7
efficiency (3/4 load) [%] 53.9
star/delta start nie/no
locked rotor torque/rated troque 1.8
locked rotor current/rated current 3.6
breakdown torque/rated torque 2.8
locked rotor torque [Nm] 14.33
locked rotor current at rated voltage 1 [A] 8.6
breakdown torque [Nm] 22
winding connection Y

technical data

weight (IMB3) [kg] 24.4
DE bearing 6206 2Z
NDE bearing 6206 2Z
position of terminal box top
terminal box rotation yes
number of terminals 6
number of cable outlets 2
gland M 20 x 1.5
thermal protection of windings on request
grease fittings no
anticondensation heaters on request
frame aluminium
end shields aluminium
foot aluminium
relative humidity [%] 95
climate on request
rotor inertia [kgm2] 0.0094

mounting arrangements

IM 1001 / IM B3 Sg_100.pdf
IM 1051 / IM B6 Sg_100.pdf
IM 1061 / IM B7 Sg_100.pdf
IM 1071 / IM B8 Sg_100.pdf
IM 2001 / IM B35 SLg_100.pdf
IM 3001 / IM B5 SKg_100.pdf
IM 1011 / IM V5 Sg_100.pdf
IM 1031 / IM V6 Sg_100.pdf
IM 2011 / IM V15 SLg_100.pdf
IM 2031 / IM V36 available
IM 3011 / IM V1 SKg_100.pdf
IM 3031 / IM V3 SKg_100.pdf

Cantoni MotorBeselInduktaCelmaEmitEma-ElfaFanaFormitNarmodFenes