Indukta

Sg 112M-8/6W

add to notebook



basic information

insulation class F
IEC 60034-1;PN-EN 60034-
degree of protection IP 55
type of duty S1
cooling system IC 411
frame size 112

exploitation parameters

rated output [kW] 1/1.8
synchronous speed [rpm] 750/1000
frequency [Hz] 50
rated voltage 1 [V] 400
current at rated voltage 1 [A] 3.3
power factor (1/2 load) 0.43
power factor (3/4 load) 0.54
power factor (full load) 0.64
power factor (5/4 load) 0.71
rated voltage 2 [V] 380
rated voltage 3 [V] 500
current at rated voltage 2 [A] 3.5
current at rated voltage 3 [A] 2.7
power factor (1/4 load) 0.3
efficiency (5/4 load) [%] 67.5
efficiency (full load) [%] 67.8
rated output [HP] 1.36/2.4
rated torque [Nm] 13.26
number of poles 8/6
efficiency (1/4 load) [%] 43.7
efficiency (1/2 load) [%] 59.2
efficiency (3/4 load) [%] 65.5
star/delta start nie/no
locked rotor torque/rated troque 2
locked rotor current/rated current 4.3
breakdown torque/rated torque 2.7
locked rotor torque [Nm] 26.52
locked rotor current at rated voltage 1 [A] 14.2
breakdown torque [Nm] 36
winding connection Y

technical data

weight (IMB3) [kg] 32.9
DE bearing 6306 2Z
NDE bearing 6306 2Z
position of terminal box top
terminal box rotation yes
number of terminals 6
number of cable outlets 2
gland M 25 x 1.5
thermal protection of windings on request
grease fittings on request
anticondensation heaters on request
frame aluminium
end shields cast iron
foot aluminium
relative humidity [%] 95
climate on request
rotor inertia [kgm2] 0.0178

mounting arrangements

IM 1001 / IM B3 Sg_112.pdf
IM 1051 / IM B6 Sg_112.pdf
IM 1061 / IM B7 Sg_112.pdf
IM 1071 / IM B8 Sg_112.pdf
IM 2001 / IM B35 SLg_112.pdf
IM 3001 / IM B5 SKg_112.pdf
IM 1011 / IM V5 Sg_112.pdf
IM 1031 / IM V6 Sg_112.pdf
IM 2011 / IM V15 SLg_112.pdf
IM 2031 / IM V36 available
IM 3011 / IM V1 SKg_112.pdf
IM 3031 / IM V3 SKg_112.pdf

Cantoni MotorBeselInduktaCelmaEmitEma-ElfaFanaFormitNarmodFenes