» General purpose 3-phase induction motors
» three phase induction explosion-proof increased safety motors
» Three phase induction crane motors
» Three phase induction multiple-speed motors with squirrel-cage rotor
» ventilator motors
» Three phase marine motors with squirrel cage rotor
» Three phase induction motors with foreign ventilation
» Brake motors
» Special motors
»
» Three-phase rotating electrovibrators
» Three-phase one speed motors -standard- EFF2 class
» Motors with increased rated output
» Three-phase high efficiency motors EFF1 class
» Three-phase one speed motors EFF3 class
» Three-phase motors to be built-in
» Nema motors» Motors with increased rated output
» Three-phase high efficiency motors EFF1 class
» Three-phase one speed motors EFF3 class
» Three-phase motors to be built-in
» three phase induction explosion-proof increased safety motors
» Three phase induction crane motors
» Three phase induction multiple-speed motors with squirrel-cage rotor
» ventilator motors
» Three phase marine motors with squirrel cage rotor
» Three phase induction motors with foreign ventilation
» Brake motors
» Special motors
»
» Three-phase rotating electrovibrators
Three-phase one speed motors -standard- EFF2 class
Features: 
rated outputs for continuous duty,
rated voltage 380, 400 or 500 [V],
frequency 50 or 60 [Hz],
environment temperature -15 to +40[°C],
altitude up to 1000 [m] above sea level,
insulation class F,
protection degree IP 55,
one free shaft extension according to dimension drawing,
terminal box with glands and 6 terminal board with 6 terminals
| kk-01-01__standard_eff2_.pdf | catalogues | |
| pdf-sg_80-sg_200_part1.rar | catalogues | |
| pdf-sg_80-sg_200_part2.rar | catalogues | |
| sg_100_dwg.rar | catalogues | |
| sg_112_dwg.rar | catalogues | |
| sg_132_dwg_part1.rar | catalogues | |
| sg_132_dwg_part2.rar | catalogues | |
| sg_132_dwg_part3.rar | catalogues | |
| sg_160_dwg_part1.rar | catalogues | |
| sg_160_dwg_part2.rar | catalogues | |
| sg_180_dwg.rar | catalogues | |
| sg_200_dwg.rar | catalogues | |
| sg_80_dwg.rar | catalogues | |
| sh_90_dwg.rar | catalogues |
| symbol | frame size | insulation class | degree of protection | type of duty | efficiency class | |
|---|---|---|---|---|---|---|
| Sg 100L-2 | 100 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 100L-4A | 100 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 100L-4B | 100 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 100L-6 | 100 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 100L-8A | 100 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 100L-8B | 100 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 112M-2 | 112 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 112M-4 | 112 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 112M-6 | 112 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 112M-8 | 112 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 132M-4 | 132 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 132M-6A | 132 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 132M-6B | 132 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 132M-8 | 132 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 132S-2A | 132 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 132S-2B | 132 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 132S-4 | 132 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 132S-6 | 132 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 132S-8 | 132 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 160L-2 | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 160L-4 | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 160L-6 | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 160L-8 | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 160M-2A | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 160M-2B | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 160M-4 | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 160M-6 | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 160M-8A | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 160M-8B | 160 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 180L-4 | 180 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 180L-6 | 180 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 180L-8 | 180 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sg 180M-2 | 180 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sg 180M-4 | 180 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sh 90L-2 | 90 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sh 90L-4 | 90 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sh 90L-6 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | ||
| Sh 90L-8 | 90 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sh 90S-2 | 90 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sh 90S-4 | 90 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | eff2 |
| Sh 90S-6 | 90 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 | |
| Sh 90S-8 | 90 | F | IP 55 | IEC 60034-1;PN-EN 60034- | S1 |