2515_picture_584a83fcaaecc2.jpg

 

Sh400H8Ds

 

logo-emit

 

ELECTRICAL PARAMETERS

400/690

2.0

∆ or Y

5.8

50

-

355

95.1

480

95.7

1.0

95.6

S1

-

696/402

-

750

0.65

742

0.74

4569

0.77

1.2

-

GENERAL DATA

-

78

400

-

8

top/ * side

direct or Y/D or VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3200

cast iron

18.8

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1szt./łoż)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

2.0

∆ or Y

5.8

50

-

355

95.1

480

95.7

1.0

95.6

S1

-

696/402

-

750

0.65

742

0.74

4569

0.77

1.2

-

GENERAL DATA

-

78

400

-

8

top/ * side

direct or Y/D or VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3200

cast iron

18.8

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1szt./łoż)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

1.9

∆ or Y

5.7

60

-

390

95.1

522

95.7

1.0

95.7

S1

-

763/440

-

900

0.64

892

0.74

4175

0.77

1.1

-

GENERAL DATA

-

-

400

-

8

top/ * side

direct or Y/D or VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3200

cast iron

18.8

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1szt./łoż)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

460/795

1.8

∆ or Y

5.4

60

-

410

95.2

550

95.8

1.0

95.8

S1

-

698/403

-

900

0.65

891

0.75

4395

0.77

1.0

-

GENERAL DATA

-

-

400

-

8

top/ * side

direct or Y/D or VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3200

cast iron

18.8

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1szt./łoż)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand