2503_picture_584a83fcaaecc1.jpg

 

PSg112M-2B

 

logo-celma

 

ELECTRICAL PARAMETERS

400/690

3.0

∆/Y

7.0

50

-

7.5

87.5

10

87.8

1.0

86.8

S1

-

14.3/8.3

-

3000

0.74

2880

0.83

24.87

0.87

2.5

-

GENERAL DATA

-

69

112

80

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

220/380

3.0

∆/Y

7.0

50

-

7.5

87.5

10

87.8

1.0

86.8

S1

-

26.0/15.1

-

3000

0.74

2880

0.83

24.87

0.87

2.5

-

GENERAL DATA

-

69

112

80

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

230/400

3.0

∆/Y

7.0

50

-

7.5

87.5

10

87.8

1.0

86.8

S1

-

24.9/14.3

-

3000

0.74

2880

0.83

24.87

0.87

2.5

-

GENERAL DATA

-

69

112

80

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

380/660

3.0

∆/Y

7.0

50

-

7.5

87.5

10

87.8

1.0

86.8

S1

-

15.1/8.7

-

3000

0.74

2880

0.83

24.87

0.87

2.5

-

GENERAL DATA

-

69

112

80

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

3.0

∆/Y

7.0

50

-

7.5

87.5

10

87.8

1.0

86.8

S1

-

14.3/8.3

-

3000

0.74

2880

0.83

24.87

0.87

2.5

-

GENERAL DATA

-

69

112

80

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

220/380

3.0

∆/Y

7.0

60

-

7.5

87.5

10

87.8

1.0

86.8

S1

-

26.0/15.1

-

3600

0.74

3468

0.83

19.9

0.87

2.5

-

GENERAL DATA

-

74

112

85

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

230/400

3.0

∆/Y

7.0

60

-

7.5

87.5

10

87.8

1.0

86.8

S1

-

24.9/14.3

-

3600

0.74

3468

0.83

19.9

0.87

2.5

-

GENERAL DATA

-

74

112

85

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

265/460

3.1

∆/Y

7.4

60

-

8.6

87.6

11.5

88.2

1.0

87.9

S1

-

24.2/14.0

-

3600

0.74

3468

0.84

23.68

0.88

2.4

-

GENERAL DATA

-

74

112

85

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

380/660

3.0

∆/Y

7.0

60

-

7.5

87.5

10

87.8

1.0

86.8

S1

-

15.1/8.7

-

3600

0.74

3468

0.83

19.9

0.87

2.5

-

GENERAL DATA

-

74

112

85

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

3.0

∆/Y

7.0

60

-

7.5

87.5

10

87.8

1.0

86.8

S1

-

14.3/8.3

-

3600

0.74

3468

0.83

19.9

0.87

2.5

-

GENERAL DATA

-

74

112

85

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

460/795

3.1

∆/Y

7.4

60

-

8.6

87.6

11.5

88.2

1.0

87.9

S1

-

14.0/8.1

-

3600

0.74

3468

0.84

23.68

0.88

2.4

-

GENERAL DATA

-

74

112

85

2

top

DOL or Y/∆

yes

F

6306 2Z C3

yes

6306 2Z C3

IMB3/B5/B35

no

IC411

aluminium

39.0

aluminium

0.0074

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand