2621_picture_58523d861c1a41.jpg

 

3SIE400H4F

 

logo-cantoni

 

ELECTRICAL PARAMETERS

400/690

2.9

∆ or Y

8.5

50

-

600

95.5

810

96.0

1.0

96.0

S1

-

1037/599

-

1500

0.75

1491

0.84

3843

0.87

1.9

-

GENERAL DATA

IE3

83

400

-

4

top/ * side

bezpośredni. Y/D lub VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3500

cast iron

17.2

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

2.9

∆ or Y

8.5

50

-

600

95.5

810

96.0

1.0

96.0

S1

-

1037/599

-

1500

0.75

1491

0.84

3843

0.87

1.9

-

GENERAL DATA

IE3

83

400

-

4

top/ * side

bezpośredni. Y/D lub VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3500

cast iron

17.2

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

660

2.9

∆ or Y

8.5

50

-

600

95.5

810

96.0

1.0

96.0

S1

-

626

-

1500

0.75

1491

0.84

3843

0.87

1.9

-

GENERAL DATA

IE3

83

400

-

4

top/ * side

bezpośredni. Y/D lub VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3500

cast iron

17.2

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

2.9

∆ or Y

8.8

60

-

600

95.6

810

96.3

1.0

96.2

S1

-

1035/598

-

1800

0.75

1791

0.84

3200

0.87

1.9

-

GENERAL DATA

IE3

-

400

-

4

top/ * side

bezpośredni. Y/D lub VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3500

cast iron

17.2

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

460/795

2.9

∆ or Y

8.5

60

-

690

95.6

925

96.3

1.0

96.2

S1

-

1035/598

-

1800

0.75

1791

0.84

3679

0.87

1.9

-

GENERAL DATA

IE3

-

400

-

4

top/ * side

bezpośredni. Y/D lub VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3500

cast iron

17.2

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

660

2.9

∆ or Y

8.8

60

-

600

95.6

810

96.3

1.0

96.2

S1

-

627

-

1800

0.75

1791

0.84

3200

0.87

1.9

-

GENERAL DATA

IE3

-

400

-

4

top/ * side

bezpośredni. Y/D lub VSD

yes

F

6324 C3

yes

6322 C3/* 7322 BTVP

IMB3/B35/V1*

yes

IC411

cast iron

3500

cast iron

17.2

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand