2621_picture_58523d861c1a41.jpg

 

3SIE500H8E

 

logo-cantoni

 

ELECTRICAL PARAMETERS

690

2.5

∆ or Y

6.5

50

-

1000

94.8

1350

95.1

1.0

95.3

S1

-

1098

-

750

0.63

746

0.75

12802

0.80

1.1

-

GENERAL DATA

IE3

78

500

-

8

top/ * side

direct or VSD

yes

F

NU226 +6226 C3/* 6326 C3

yes

NU226 /* 7326 BTVP or QJ326N2MPA

IMB3/B35/V1*

yes

IC411

cast iron

7570

cast iron

118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

660

2.5

∆ or Y

6.5

50

-

1000

94.8

1350

95.1

1.0

95.3

S1

-

1148

-

750

0.63

746

0.75

12802

0.80

1.1

-

GENERAL DATA

IE3

78

500

-

8

top/ * side

direct or VSD

yes

F

NU226 +6226 C3/* 6326 C3

yes

NU226 /* 7326 BTVP or QJ326N2MPA

IMB3/B35/V1*

yes

IC411

cast iron

7570

cast iron

118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

690

2.5

∆ or Y

6.5

50

-

1000

94.8

1350

95.1

1.0

95.3

S1

-

1098

-

750

0.63

746

0.75

12802

0.80

1.1

-

GENERAL DATA

IE3

78

500

-

8

top/ * side

direct or VSD

yes

F

NU226 +6226 C3/* 6326 C3

yes

NU226 /* 7326 BTVP or QJ326N2MPA

IMB3/B35/V1*

yes

IC411

cast iron

7570

cast iron

118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

660

2.5

∆ or Y

7.0

60

-

1000

95.0

1350

95.5

1.0

95.5

S1

-

1145

-

900

0.63

896

0.75

10658

0.80

1.1

-

GENERAL DATA

IE3

-

500

-

8

top/ * side

direct or VSD

yes

F

NU226 +6226 C3/* 6326 C3

yes

NU226 /* 7326 BTVP or QJ326N2MPA

IMB3/B35/V1*

yes

IC411

cast iron

7570

cast iron

118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

690

2.5

∆ or Y

7.0

60

-

1000

95.0

1350

95.5

1.0

95.5

S1

-

1095

-

900

0.63

896

0.75

10658

0.80

1.1

-

GENERAL DATA

IE3

-

500

-

8

top/ * side

direct or VSD

yes

F

NU226 +6226 C3/* 6326 C3

yes

NU226 /* 7326 BTVP or QJ326N2MPA

IMB3/B35/V1*

yes

IC411

cast iron

7570

cast iron

118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand