2622_picture_584a828aa981c1.jpg

 

2SIE355H6D

 

logo-cantoni

 

ELECTRICAL PARAMETERS

400/690

2.3

∆ or Y

7.5

50

-

355

95.6

480

95.9

1.0

95.7

S1

-

630/364

-

1000

0.76

991

0.83

3421

0.85

1.8

-

GENERAL DATA

IE2

78

355

-

6

top/ * side

DOL, Y/∆ or VSD

yes

F

6322 C3

yes

6322 C3

IMB3/B35/V1*

yes

IC411

cast iron

2540

cast iron

14.3

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

380/660

2.2

∆ or Y

7.5

50

-

355

95.4

480

95.7

1.0

95.5

S1

-

664/383

-

1000

0.75

990

0.83

3425

0.85

1.9

-

GENERAL DATA

IE2

78

355

-

6

top/ * side

DOL, Y/∆ or VSD

yes

F

6322 C3

yes

6322 C3

IMB3/B35/V1*

yes

IC411

cast iron

2540

cast iron

14.3

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

2.3

∆ or Y

7.5

50

-

355

95.6

480

95.9

1.0

95.7

S1

-

630/364

-

1000

0.76

991

0.83

3421

0.85

1.8

-

GENERAL DATA

IE2

78

355

-

6

top/ * side

DOL, Y/∆ or VSD

yes

F

6322 C3

yes

6322 C3

IMB3/B35/V1*

yes

IC411

cast iron

2540

cast iron

14.3

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

380/660

2.1

∆ or Y

8.0

60

-

355

95.0

480

95.6

1.0

95.6

S1

-

648/374

-

1200

0.79

1191

0.85

2847

0.87

1.4

-

GENERAL DATA

IE2

-

355

-

6

top/ * side

DOL, Y/∆ or VSD

yes

F

6322 C3

yes

6322 C3

IMB3/B35/V1*

yes

IC411

cast iron

2540

cast iron

14.3

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

2.1

∆ or Y

8.0

60

-

355

95.0

480

95.6

1.0

95.6

S1

-

616/356

-

1200

0.79

1191

0.85

2847

0.87

1.4

-

GENERAL DATA

IE2

-

355

-

6

top/ * side

DOL, Y/∆ or VSD

yes

F

6322 C3

yes

6322 C3

IMB3/B35/V1*

yes

IC411

cast iron

2540

cast iron

14.3

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

460/795

2.1

∆ or Y

8.0

60

-

355

95.0

480

95.6

1.0

95.6

S1

-

536/309

-

1200

0.79

1191

0.85

2847

0.87

1.4

-

GENERAL DATA

IE2

-

355

-

6

top/ * side

DOL, Y/∆ or VSD

yes

F

6322 C3

yes

6322 C3

IMB3/B35/V1*

yes

IC411

cast iron

2540

cast iron

14.3

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

2 x Pt100 (1 pc/bearing)

2

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand